Red Plague -
). It occurs when silver-plated copper is exposed to moisture and oxygen, typically due to damage or gaps in the silver plating.
: It is most common in high-humidity environments. Some manufacturers minimize risk by ensuring a minimum plating thickness (e.g., 40 microinches). Red Plague
In the aerospace and electronics industries, "Red Plague" is the nickname for corrosion ( Red Plague